XML Feed for RxPG News   Add RxPG News Headlines to My Yahoo!   Javascript Syndication for RxPG News

Research Health World General
 
  Home
 
 Latest Research
 Cancer
 Psychiatry
 Genetics
 Surgery
 Aging
 Ophthalmology
 Gynaecology
 Neurosciences
 Pharmacology
 Cardiology
 Obstetrics
 Infectious Diseases
 Respiratory Medicine
 Pathology
 Endocrinology
 Immunology
 Nephrology
 Gastroenterology
 Biotechnology
 Radiology
 Dermatology
 Microbiology
 Haematology
 Dental
 ENT
 Environment
 Embryology
 Orthopedics
 Metabolism
 Anaethesia
 Paediatrics
 Public Health
 Urology
 Musculoskeletal
 Clinical Trials
 Physiology
 Biochemistry
 Cytology
 Traumatology
 Rheumatology
 
 Medical News
 Health
 Opinion
 Healthcare
 Professionals
 Launch
 Awards & Prizes
 
 Careers
 Medical
 Nursing
 Dental
 
 Special Topics
 Euthanasia
 Ethics
 Evolution
 Odd Medical News
 Feature
 
 World News
 Tsunami
 Epidemics
 Climate
 Business
Search

Last Updated: Aug 19th, 2006 - 22:18:38

Radiology Channel
subscribe to Radiology newsletter

Latest Research : Radiology

   DISCUSS   |   EMAIL   |   PRINT
Remote Detection Makes NMR Compatible with Microfluidics
Oct 11, 2005, 00:48, Reviewed by: Dr.

�With remote detection of NMR, we don�t need the addition of markers that perturb the flow because we can use the spins of the hyperpolarized xenon nuclei. Also, when we apply the hyperpolarized xenon for the encoding step of remote detection, we can individually tag a fluid sample in any and all points within the device, whereas we can inject a fluorescent marker only at a device�s inlet.�

 
A breakthrough in the technology of nuclear magnetic resonance (NMR), one of the most powerful analytic tools known to science, is opening the door to new applications in microfluidic chips, devices for studying super-tiny amounts of fluids. A team of scientists with Lawrence Berkeley National Laboratory (Berkeley Lab) and the University of California, Berkeley, has demonstrated a means by which NMR can be made compatible with microfluidic �lab-on-a-chip� devices. �Our novel methodology bypasses the long-standing problem of optimizing the two basic steps of NMR, signal encoding and detection, by physically separating them, and, at the same time, adds an important dimension to the study of fluid flow dynamics with the possibility of time-of-flight measurements,� said Alexander Pines, one of the world�s leading authorities on NMR technology. Pines holds a joint appointment as a chemist with Berkeley Lab�s Materials Sciences Division and with UC Berkeley, where he is the Glenn T. Seaborg Professor of Chemistry.

The technique in which NMR signal encoding and detection are carried out independently (in a conventional NMR setup, the two actions take place within a single device) is called remote NMR detection. In a paper published in the online edition of the Proceedings of the National Academy of Sciences (PNAS), for the week of October 3, Pines and his collaborators describe the use of remote NMR to study the flow of gases through microfluidic devices.

�Remote detection of the NMR signal overcomes the sensitivity limitation of NMR and enables spatially resolved imaging in addition to time-of-flight measurements,� said chemist Christian Hilty, a member of Pines� research group and the principal author of the PNAS paper. We can use it to measure microfluidic flow without the introduction of foreign tracer particles. This is important for the design and the operation of microfluidic devices.�

The work is supported by the U.S. Department of Energy�s Basic Energy Sciences program in the Office of Science.

When a sample is exposed to a strong external magnetic field, these "bar magnets" attempt to align their axes along the lines of magnetic force. The alignment is not exact, resulting in a wobbly rotation about the magnetic field lines that is unique for each type of nuclei.

If, while exposed to the magnetic field, the nuclei in a sample are also subjected to a sequence of radiofrequency (rf) pulses, they will absorb and re-emit energy at characteristic frequencies. This is called the signal �encoding� phase of NMR. In the detection phase, the frequencies of these encoded signals are measured to obtain an NMR spectrum. While NMR has long been a powerful tool for studying the chemical composition of macroscopic samples, its application to microfluidic chip devices has been hampered by low sensitivity. Obtaining an NMR signal depends upon an excess of nuclei in a sample with spins pointing in one direction or the other, but the natural population difference in a typical fluid sample, even under a powerful magnetic field, is usually no more than one in 100,000 at room temperature.

To overcome this low spin polarization so they can measure gas flow, Pines and his research group have been injecting their samples with xenon whose atomic nuclei have been hyperpolarized by laser light. Hyperpolarized xenon boosts the NMR sensitivity of a sample by at least four orders of magnitude, and, xenon being inert, does not interfere with the other sample constituents as it is carried along in the flow.

When working with microfludic samples of gas, Pines and his collaborators apply their NMR encoding technique to the hyperpolarized xenon. With its long spin-relaxation time (several minutes), hyperpolarized xenon is well-suited for transporting the encoded NMR information to a separate site for detection. By staging the encoding and detection phases at separate sites, each site can be customized to obtain optimal results.

�Xenon�s long spin-relaxation time (several minutes), make it an ideal carrier of an NMR signal for remote measurements of gas flow,� said Hilty.

Microfluidic devices are essentially miniaturized chemistry laboratories, featuring a series of micrometer-sized channels etched into a chip in which nanoliter-sized samples of fluids can be analyzed. Using remote NMR instead offers several advantages.

�With remote detection of NMR, we don�t need the addition of markers that perturb the flow because we can use the spins of the hyperpolarized xenon nuclei,� said Hilty. �Also, when we apply the hyperpolarized xenon for the encoding step of remote detection, we can individually tag a fluid sample in any and all points within the device, whereas we can inject a fluorescent marker only at a device�s inlet.�

According to Hilty and Pines, their NMR remote detection technology is ready to be applied to any existing microfluidic device, so long as the fluid is transported to the detection site within the spin relaxation time of encoded NMR information.

�In our PNAS paper, we describe an application in which we measure gas flow in microfluidic devices by remote detection of NMR,� said Hilty. Pines and his research group are working on the development of alternative, less expensive means of detecting encoded NMR signals � for example, a magnetometer. According to Hilty, preliminary results on this line of research have been promising.
 

- Proceedings of the National Academy of Sciences (PNAS)
 

www.pnas.org/papbyrecent.shtml

 
Subscribe to Radiology Newsletter
E-mail Address:

 

Berkeley Lab is a U.S. Department of Energy national laboratory located in Berkeley, California. It conducts unclassified scientific research and is managed by the University of California. Visit our Website at www.lbl.gov.

Related Radiology News

New way of tracking muscle damage from radiation
Audit shows excellent performance of radiologists in interpreting mammograms
Comparing MDCT and digital radiography in orthopedic patients
New MRI technique shows emphysema in asymptomatic smokers
Safety profile for CT colonography (CTC) favorable
Modulating tube current to account for body symmetry reduces radiation exposure in CT
Training on virtual 'patient' improves carotid angiography skills
Radiologic signs more than double sensitivity of MRIs
CT Enteroclysis Has a Superior Diagnostic Value in Crohn's Disease
Characteristic Cardiac Scar Pattern Predicts Risk Of Fatal Arrhythmias


For any corrections of factual information, to contact the editors or to send any medical news or health news press releases, use feedback form

Top of Page

 

© Copyright 2004 onwards by RxPG Medical Solutions Private Limited
Contact Us