RxPG News Feed for RxPG News

Medical Research Health Special Topics World
  Home
 
   Health
 Aging
 Asian Health
 Events
 Fitness
 Food & Nutrition
 Happiness
 Men's Health
 Mental Health
 Occupational Health
 Parenting
 Public Health
 Sleep Hygiene
 Women's Health
 
   Healthcare
 Africa
 Australia
 Canada Healthcare
 China Healthcare
 India Healthcare
 New Zealand
 South Africa
 UK
 USA
 World Healthcare
 
 Latest Research
 Aging
 Alternative Medicine
 Anaethesia
 Biochemistry
 Biotechnology
 Cancer
 Cardiology
 Clinical Trials
 Cytology
 Dental
 Dermatology
 Embryology
 Endocrinology
 ENT
 Environment
 Epidemiology
 Gastroenterology
 Genetics
 Gynaecology
 Haematology
 Immunology
 Infectious Diseases
 Medicine
 Metabolism
 Microbiology
 Musculoskeletal
 Nephrology
 Neurosciences
 Obstetrics
 Ophthalmology
 Orthopedics
 Paediatrics
 Pathology
 Pharmacology
 Physiology
 Physiotherapy
 Psychiatry
 Radiology
 Rheumatology
 Sports Medicine
 Surgery
 Toxicology
 Urology
 
   Medical News
 Awards & Prizes
 Epidemics
 Launch
 Opinion
 Professionals
 
   Special Topics
 Ethics
 Euthanasia
 Evolution
 Feature
 Odd Medical News
 Climate

Last Updated: Sep 15, 2017 - 4:49:58 AM
Research Article
Latest Research Channel

subscribe to Latest Research newsletter
Latest Research

   EMAIL   |   PRINT
Potential benefits of remote follow-up of ICD patients

Aug 29, 2011 - 4:00:00 AM

Nevertheless, the non-inferiority hypothesis of the trial with a strict non-inferiority margin of 5% was not confirmed, as the event rate difference between the two groups was 1.7%, with a 95% confidence interval of -0.3 to 6.4.


 
[RxPG] Results from the EVATEL (EVAluation of TELe follow-up) trial are the first in Europe to demonstrate potential safety and efficacy benefits from the remote follow-up of ICD patients. The trial was conducted in France, with the financial support of the French Ministry for Health and independent of any manufacturer grants.

ICDs (implantable cardioverter defibrillators) are devices routinely implanted in patients at risk of sudden cardiac death as a result of rhythm disturbances. The expending indications for ICDs are expected to have an impact on follow-up strategy, as the number of patients with ICDs is increasing rapidly.

Currently, explains investigator Dr Philippe Mabo form the University Hospital of Rennes, France, regular in-clinic follow-up must be performed every three months, according to manufacturer guidelines. But there are two drawbacks to the in-clinic follow-up - they're time-constrained for both the patient and the clinic, and there's no link between the time of the appointment and the clinical event or device malfunction. So there's a clinical need to consider new follow-up strategy.

In response, several manufacturers have developed new technologies which allow the remote transmission of information from the device and on its therapeutic effect. Critical data can be transmitted at any time on system integrity or unexpected events - for example, lead integrity, battery status or ineffectively delivered therapy. Data stored in the device are transmitted by phone from the patient's home to the implant centre, with website access to the data.

In this context, said Dr Mabo, remote device follow-up seems to be a promising technique for device follow-up. But the technology needed clinical validation in terms of safety, efficacy and cost-efficiency, which were the objectives of the EVATEL trial.

The study included 1501 patients from 30 French centres enrolled between January 2008 and January 2010. They were each followed-up every three months for an overall period of one year. The last follow-up was performed in January 2011. The characteristics of the subjects were comparable to those of an ICD trial or registry, with a mean age of 59 years and the majority male (85%). Half the patient received conventional follow-up at the implant centre, the other half were followed remotely. The primary end-point of the trial was a clinical composite of death (all causes), cardiovascular hospitalisation, and ineffective or inappropriate therapy delivered by the device.

The primary endpoint was validated in 28.5% of the control group and 30.2% of the remote group, thus indicating no difference in outcome between the groups. In addition, there were no statistically significant differences between the two groups in time to occurrence of the first primary endpoint (p=0.71) and the one-year survival rate (p=0.31). The number of inappropriate therapies was lower in the remote group (4.7%) as compared to the control group (7.5%) (p=0.03).

Nevertheless, the non-inferiority hypothesis of the trial with a strict non-inferiority margin of 5% was not confirmed, as the event rate difference between the two groups was 1.7%, with a 95% confidence interval of -0.3 to 6.4.

Commenting on the results, Dr Mabo said: The remote follow-up of patients implanted with an ICD seems to be a safe alternative to conventional in-office follow-up. However, for the widespread uptake of this new strategy - at least in France - reimbursement from the healthcare system will be needed. We hope that it will be available soon in France.



Related Latest Research News


Subscribe to Latest Research Newsletter

Enter your email address:


 Feedback
For any corrections of factual information, to contact the editors or to send any medical news or health news press releases, use feedback form

Top of Page

 
Contact us

RxPG Online

Nerve

Online ACLS Certification

 

    Full Text RSS

© All rights reserved by RxPG Medical Solutions Private Limited (India)