RxPG News Feed for RxPG News

Medical Research Health Special Topics World
  Home
 
   Health
 Aging
 Asian Health
 Events
 Fitness
 Food & Nutrition
 Happiness
 Men's Health
 Mental Health
 Occupational Health
 Parenting
 Public Health
 Sleep Hygiene
 Women's Health
 
   Healthcare
 Africa
 Australia
 Canada Healthcare
 China Healthcare
 India Healthcare
 New Zealand
 South Africa
 UK
 USA
 World Healthcare
 
   Latest Research
 Aging
 Alternative Medicine
 Anaethesia
 Biochemistry
 Biotechnology
 Cancer
 Cardiology
 Clinical Trials
 Cytology
 Dental
 Dermatology
 Embryology
 Endocrinology
 ENT
 Environment
 Epidemiology
 Gastroenterology
 Genetics
 Gynaecology
 Haematology
 Immunology
 Infectious Diseases
 Medicine
 Metabolism
 Microbiology
 Musculoskeletal
 Nephrology
 Neurosciences
 Obstetrics
 Ophthalmology
 Orthopedics
 Paediatrics
 Pathology
 Pharmacology
 Physiology
 Physiotherapy
 Psychiatry
 Radiology
 Rheumatology
 Sports Medicine
 Surgery
 Toxicology
 Urology
 
   Medical News
 Awards & Prizes
 Epidemics
 Launch
 Opinion
 Professionals
 
   Special Topics
 Ethics
 Euthanasia
 Evolution
 Feature
 Odd Medical News
 Climate

Last Updated: Oct 11, 2012 - 10:22:56 PM
Radiology Channel

subscribe to Radiology newsletter
Latest Research : Radiology

   EMAIL   |   PRINT
Remote Detection Makes NMR Compatible with Microfluidics

Oct 11, 2005 - 12:48:00 AM
“With remote detection of NMR, we don’t need the addition of markers that perturb the flow because we can use the spins of the hyperpolarized xenon nuclei. Also, when we apply the hyperpolarized xenon for the encoding step of remote detection, we can individually tag a fluid sample in any and all points within the device, whereas we can inject a fluorescent marker only at a device’s inlet.”

 
[RxPG] A breakthrough in the technology of nuclear magnetic resonance (NMR), one of the most powerful analytic tools known to science, is opening the door to new applications in microfluidic chips, devices for studying super-tiny amounts of fluids. A team of scientists with Lawrence Berkeley National Laboratory (Berkeley Lab) and the University of California, Berkeley, has demonstrated a means by which NMR can be made compatible with microfluidic “lab-on-a-chip” devices. “Our novel methodology bypasses the long-standing problem of optimizing the two basic steps of NMR, signal encoding and detection, by physically separating them, and, at the same time, adds an important dimension to the study of fluid flow dynamics with the possibility of time-of-flight measurements,” said Alexander Pines, one of the world’s leading authorities on NMR technology. Pines holds a joint appointment as a chemist with Berkeley Lab’s Materials Sciences Division and with UC Berkeley, where he is the Glenn T. Seaborg Professor of Chemistry.

The technique in which NMR signal encoding and detection are carried out independently (in a conventional NMR setup, the two actions take place within a single device) is called remote NMR detection. In a paper published in the online edition of the Proceedings of the National Academy of Sciences (PNAS), for the week of October 3, Pines and his collaborators describe the use of remote NMR to study the flow of gases through microfluidic devices.

“Remote detection of the NMR signal overcomes the sensitivity limitation of NMR and enables spatially resolved imaging in addition to time-of-flight measurements,” said chemist Christian Hilty, a member of Pines’ research group and the principal author of the PNAS paper. We can use it to measure microfluidic flow without the introduction of foreign tracer particles. This is important for the design and the operation of microfluidic devices.”

The work is supported by the U.S. Department of Energy’s Basic Energy Sciences program in the Office of Science.

When a sample is exposed to a strong external magnetic field, these "bar magnets" attempt to align their axes along the lines of magnetic force. The alignment is not exact, resulting in a wobbly rotation about the magnetic field lines that is unique for each type of nuclei.

If, while exposed to the magnetic field, the nuclei in a sample are also subjected to a sequence of radiofrequency (rf) pulses, they will absorb and re-emit energy at characteristic frequencies. This is called the signal “encoding” phase of NMR. In the detection phase, the frequencies of these encoded signals are measured to obtain an NMR spectrum. While NMR has long been a powerful tool for studying the chemical composition of macroscopic samples, its application to microfluidic chip devices has been hampered by low sensitivity. Obtaining an NMR signal depends upon an excess of nuclei in a sample with spins pointing in one direction or the other, but the natural population difference in a typical fluid sample, even under a powerful magnetic field, is usually no more than one in 100,000 at room temperature.

To overcome this low spin polarization so they can measure gas flow, Pines and his research group have been injecting their samples with xenon whose atomic nuclei have been hyperpolarized by laser light. Hyperpolarized xenon boosts the NMR sensitivity of a sample by at least four orders of magnitude, and, xenon being inert, does not interfere with the other sample constituents as it is carried along in the flow.

When working with microfludic samples of gas, Pines and his collaborators apply their NMR encoding technique to the hyperpolarized xenon. With its long spin-relaxation time (several minutes), hyperpolarized xenon is well-suited for transporting the encoded NMR information to a separate site for detection. By staging the encoding and detection phases at separate sites, each site can be customized to obtain optimal results.

“Xenon’s long spin-relaxation time (several minutes), make it an ideal carrier of an NMR signal for remote measurements of gas flow,” said Hilty.

Microfluidic devices are essentially miniaturized chemistry laboratories, featuring a series of micrometer-sized channels etched into a chip in which nanoliter-sized samples of fluids can be analyzed. Using remote NMR instead offers several advantages.

“With remote detection of NMR, we don’t need the addition of markers that perturb the flow because we can use the spins of the hyperpolarized xenon nuclei,” said Hilty. “Also, when we apply the hyperpolarized xenon for the encoding step of remote detection, we can individually tag a fluid sample in any and all points within the device, whereas we can inject a fluorescent marker only at a device’s inlet.”

According to Hilty and Pines, their NMR remote detection technology is ready to be applied to any existing microfluidic device, so long as the fluid is transported to the detection site within the spin relaxation time of encoded NMR information.

“In our PNAS paper, we describe an application in which we measure gas flow in microfluidic devices by remote detection of NMR,” said Hilty. Pines and his research group are working on the development of alternative, less expensive means of detecting encoded NMR signals — for example, a magnetometer. According to Hilty, preliminary results on this line of research have been promising.



Publication: Proceedings of the National Academy of Sciences (PNAS)
On the web: www.pnas.org/papbyrecent.shtml 

Advertise in this space for $10 per month. Contact us today.


Related Radiology News
First breast PET/CT scanner to visualize suspected cancerous lesions in 3-D.
Drug eluting stents may save limbs
Combining patient photos with imaging improves diagnosis
Ultrasound Imaging Improved by New Computer Model
Computer model improves ultrasound image
Indian American develops tool to image tumours
Injectable Microfoam for Varicose Veins safe in Phase II trial
Newer Nonionic Contrast Agents Safe for Children
Electromagnetic breast imaging techniques offer high contrast and ability to distinguish between healthy breast tissue and abnormal tissue
Percutaneous radiofrequency ablation of liver tumors prove safe and effective

Subscribe to Radiology Newsletter

Enter your email address:


 Additional information about the news article